Inductive sensor NBN40-U1K-N0

pepperl

$110.00

'General specifications', 'Switching functionNormally closed (NC)', 'Output typeNAMUR', 'Rated operating distance40 mm', 'Installationnon-flush', 'Assured operating distance0 ... 32.4 mm', 'Actual operating distance36 ... 44 mm', 'Reduction factor rAl 0.45', 'Reduction factor rCu 0.45', 'Reduction factor r304 0.8', 'Output type2-wire', 'Nominal ratings', 'Nominal voltage8.2 V (Ri approx. 1 kΩ)', 'Switching frequency0 ... 100 Hz', 'Hysteresis1 ... 15 typ. 5 %', 'Reverse polarity protectionreverse polarity protected', 'Short-circuit protectionyes', 'Current consumption', 'Measuring plate not detectedâ‰?3 mA', 'Measuring plate detectedâ‰?1 mA', 'Switching state indicatorLED, yellow', 'Functional safety related parameters', 'MTTFd1415 a', 'Mission Time (TM)20 a', 'Diagnostic Coverage (DC)0 %', 'Compliance with standards and directives', 'Standard conformity', 'NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999', 'Electromagnetic compatibilityNE 21:2007', 'StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012', 'Approvals and certificates', 'IECEx approval', 'Equipment protection level GaIECEx PTB 11.0021X', 'Equipment protection level GbIECEx PTB 11.0021X', 'Equipment protection level DaIECEx PTB 11.0021X', 'Equipment protection level MbIECEx PTB 11.0021X', 'ATEX approval', 'Equipment protection level GaPTB 00 ATEX 2032 X', 'Equipment protection level GbPTB 00 ATEX 2032 X', 'Equipment protection level Gc (ic)PF13CERT2895 X', 'Equipment protection level DaPTB 00 ATEX 2032 X', 'EAC conformityTRxa0CU 012/2011', 'UL approvalcULus Listed, General Purpose', 'Ordinary LocationE87056', 'Hazardous LocationE501628', 'Control drawing116-0451', 'CCC approval', 'Hazardous Location2020322315002303', 'NEPSI approval', 'NEPSI certificateGYJ16.1394X', 'Marine approvalDNVGL TAA00001A5', 'Ambient conditions', 'Ambient temperature-25 ... 100 °C (-13 ... 212 °F)', 'Storage temperature-40 ... 100 °C (-40 ... 212 °F)', 'Mechanical specifications', 'Connection typescrew terminals', 'Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %', 'Core cross-sectionup to 2.5 mm2 , stripped insulation length: 7 mm', 'Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2', 'Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2', 'Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 9.1 mm , screw-in depth max. 9.1 mm', 'Housing materialPA', 'Sensing facePA', 'Degree of protectionIP66 / IP68 / IP69K', 'Mass225 g', 'NoteTightening torque: 1.8 Nm (housing)', 'General information', 'Use in the hazardous areasee instruction manuals'


×

Call for Price

I agree to my email being stored and used to receive the newsletter.